Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE > ENTRANCE CABLE
We found 8 results matching your criteria.
Sort By:
Page of 1
Southwire SEU Service Entrance Cable Southwire SEU Service Entrance Cable, 2-2-2 AWG, 200 ft, XHHW-2, THWN

Cross-linked polyethylene (XLPE) insulation. Insulated conductors laid parallel with bare ground wires helically wound around core. Covered with a reinforced binder tape. Sunlight resistant gray PVC jacket. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius in wet or dry locations, 600 volt. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.

Our Price: $1.59
Southwire 2-2-4-6X500AL USE In-Use Service Entrance Cable Wire Southwire 2-2-4-6X500AL USE In-Use Service Entrance Cable Wire, 2-2-4-6 AWG, 500 ft

Used to connect mobile homes to a supply of electricity where permanent wiring is required as specific by NEC Article 550-24 and complies with NEC Article 338-1. Compact stranded 8000 series aluminum alloy. 600 volt. Cross-linked, polyethylene (XLPE). Types USE-2/RHH/RH, W-2. Approved for direct burial up to 90 degrees Celsius. Quadruplex cable conductor construction. UL Listed.

Our Price: $1.79
Southwire SEU Service Entrance Cable Wire Southwire SEU Service Entrance Cable Wire, 8-8-8 AWG, 250 ft, XHHW, THHN/THWN

Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.

Our Price: $1.89
Southwire SEU Service Entrance Cable Wire Southwire SEU Service Entrance Cable Wire, 6-6-8 AWG, 200 ft, XHHW, THHN/THWN

Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.

Our Price: $2.09
Southwire SEU Service Entrance Cable Wire Southwire SEU Service Entrance Cable Wire, 6-6-6 AWG, 150 ft, XHHW, THHN/THWN

Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.

Our Price: $2.39
Southwire MBL Service Entrance Cable Wire Southwire MBL Service Entrance Cable Wire, 4/0-4/0-2/0-4 AWG, 500 ft, Cross Linked Polyethylene

Used to connect mobile homes to a supply of electricity where permanent wiring is required as specific by NEC Article 550-24 and complies with NEC Article 338-1. Compact stranded 8000 series aluminum alloy. 600 volt. Cross-linked, polyethylene (XLPE). Types USE-2/RHH/RH, W-2. Approved for direct burial up to 90 degrees Celsius. Quadruplex cable conductor construction. UL Listed.

Our Price: $3.59
Southwire SEU Service Entrance Cable Southwire SEU Service Entrance Cable, 4/0-4/0-4/0 AWG, 100 ft, XHHW-2, THWN

Cross-linked polyethylene (XLPE) insulation. Insulated conductors laid parallel with bare ground wires helically wound around core. Covered with a reinforced binder tape. Sunlight resistant gray PVC jacket. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius in wet or dry locations, 600 volt. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.

Our Price: $3.69
Southwire SEU Service Entrance Cable Wire Southwire SEU Service Entrance Cable Wire, 4-4-4 AWG, 150 ft, XHHW, THHN/THWN

Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.

Our Price: $4.39